中文版

Your location: Home > Support > Product manual
Support

Support Repair Instructions Product manual
VIII, maintenance and repair
Maintenance and Repair
1, the assembly of the maintenance and failure analysis
(1) plus regular transmission oil
(2) regular inspection of the electrical parts of the leakage security.
(3) regular part of each orbit demagnetization.
Common Faults and exclusion method:
Troubleshooting Treatment
Main vibration does not vibrate 1, the power switch is broken; if it is: replace the 2, the coil is burned out: If you are: replacement of
Not on the gasket sets Check the track down the correct position: adjusted
Hopper does not go Check the track down the correct position: Adjust 1, regulating knob is burned: If you are: replacement of 2, the coil is burned out: If you are: replacement of 3, spring is loose: Adjust
Track stuck gasket 1, check whether there are glitches gasket, gasket thickness is consistent if it is: Replace the gasket 2 and see whether the track is too thin or too thick sandwich: adjust track and steel skin butt is not correct: Adjust
After the screw will turn down Orbital docking with the steel skin is not correct: Adjust
Screw over the sensor did not respond 1, check the sensor is broken: if it is: replace the 2 sensors too far away: Adjust
2, the vibrating plate of maintenance and failure analysis
(1) regular inspection of all parts of the screws for loose or out of the phenomenon
(2) changes regularly check whether the space, which is too much dust, spring steel have broken
(3) If the core and armature with crash, shall immediately repair
(4) Electrical equipment: check the control box of the wiring is loose or off, if it fall off, that is connected by schematic to tighten
General failure and the reasons:
No. Symptom Possible Cause Results
1 Power, the machine does not vibrate ①Fuse broken②Short circuit of winding wires③Joints are decapitated Completely stop the machine
2 Weak vibration, adjusting potentiometer small or no effect on the amplitude of the reflected ①Rectifier breakdown②Coil Polarity Error③Plug gap④Debris stuck between the spring plate ①The rectifier circuit, no different phenomena②Current increases③Amplitude decreases
3 Machine noise, adjust the potentiometer shown after the irregularity, the collision ①There reed plate fracture②Trough cross connection with the coupling screw loose or damaged Lost tuning, the current amplitude decreases, production decline
4 Pressure of the machine by the silo, the amplitude decreases Hopper discharge port design is wrong, so that the pressure tank to withstand excessive Amplitude decreases
5 Yield normal, but the current is too high Air gap too large Current increased
© Ming boring Hardware Machinery Co., Ltd.